CT MCi Parameter Temp

Navigation:  Libraries > CT Device Parameter Libraries >

CT MCi Parameter Temp

Previous pageReturn to chapter overviewNext page

 

The library CT MCi Parameter Library is installed to a device by default to allow easy access to the module parameters.

 

In the library are all parameters available for the MCi option module.

 

 

Viewing available menus and parameters
Viewing online values

 

 

Viewing available menus and parameters

 

To view available parameters select the Library Manager attached to a device and select the library.

 

Note: Menus have 2 access methods:

 

Self.MenuName.ParameterName or,
ReadUserParameter<Type>(Slot, Menu, Parameter)

 

Note: To access parameters on the module user code is running value 255 can be used in the slot function parameter meaning 'this'.

 

MciLibraryManager

 

 

Information available:

Data Type
Parameter Caption
Drive parameter number
Min / Max range

 

 

Viewing Online Values

 

When online a menu can be opened and values read from the module - in addition values can be entered into the Prepared Value column and sent to the module.

 

Note: A parameter from the menu opened MUST be referenced in an application to view values.

 

MciLibraryManager_online